Rotational Viscometer
Detailed Product Description
Purpose:
This instrument is produced by the standard of T0625-2000. It is used to test the
apparent viscosity of the road bitumen, and it is also used to test viscosity of the thermo-sol, paraffin wax, medicament and high polymer.
NDJ-1C Technical Parameters:
Measure Range: 100200000mPa·s
Stirrer parameter: 21#27#28#29#
Stirrer rotating speed: 5102050r/min
Measure mode: automatic, hand-operated
Temperature control range: room temperature200
Temperature control accuracy: ±0.1
Volume of inner bag: 10cc
Working environment:
Environment temperature: 5-35
Environment humidity: ≤80
Electric source: AC 220V±10V 50Hz±1Hz
No electromagnetic, no shake, no active gas
NDJ-1D
Technical Parameters:
Measure Range: 1002×106mPa·s(optional 30# up to 4×106MPa·s)
Stirrer parameter: 21#27#28#29# (optional 30#)
Stirrer rotating speed: 0.5125102050 r/min
Measure mode: automatic, hand-operated
Temperature control range: room temperature200
Temperature control accuracy: ±0.1
Volume of inner bag: 10cc
Working environment:
Environment temperature: 5~35
Environment humidity: ≤80
Electric source: AC 220V±10V 50Hz±1Hz
No electromagnetic, no shake, no active gas
NDJ-1F Main function:
1. Intelligent stepless speed regulation, ultra-bright LCD displays in Chinese Characters;
2. Using temperature controller of intelligent type to set, control and display the bath
temperature.
3. Matched with micro-printer, it can plot measurement report.
4. Using serial port cable, it can communicate with computer directly;
5. Using little sample operating mode, the maximum cubage of sample is approximately 20 ml. Technical specification:
1. Measurement range: 25mPa·s 1×107mPas (If choose to equip the 30
measurement rotor, it can extended to 2×107mPa·s );
2. Rotor: 21,27,28,29total four piece.( 30 measurement rotor is optional );
3. Rotor rotation speed: 0.1200 r/min;
4. Measurement error: ±2% (F.S);
5. Controlling temperature range of heater: room temperature200
6. Controlling temperature accuracy of the heater: ±0.1
7. Sample container cubage: 20ml;
8. Power supply: AC 220 V±10 % , 50 Hz;
9. Working environment:
Ambient temperature: 5~35 (attention: environment temperature should be 5 lower than the
controlling temperature of heater.);